Microcurrent Therapy Used to Normalize Electrical Patterns in Abnormal Tissue for the Promotion of Cellular Functions and Reduction of Inflammation
The Electro-Equiscope®, available since 2012, represents a sophisticated integration of microcurrent therapy, advanced signal processing and real-time feedback control. Its engineering principles are rooted in fundamental electrical engineering and physics concepts, tailored to address the complex bioelectrical environment of the human body. By normalizing cellular electrical activity, it promotes healing and reduces pain, offering a non-invasive therapeutic option with broad applications in medicine and wellness.
Microcurrent therapy employs currents in the microampere (µA) range. These currents are extremely low intensity, typically in the range of 1-999 µA, mimicking the natural electrical currents produced by the human body. The primary objective is to stimulate cellular activity and repair by enhancing cellular energy (ATP) production and reducing inflammation.
This microcurrent device operates based on Ohm’s Law Application, or Ohm (V = IR), where the voltage (V) applied across a tissue results in a current (I) that depends on the tissue’s resistance (R). The device measures the impedance of tissues to determine the appropriate current to apply. This involves a real-time feedback loop that continuously adjusts the current to maintain the desired therapeutic effect.
The Electro-Equiscope® utilizes Bioelectrical Impedance Analysis (BIA) to assess the electrical properties of the body’s tissues. BIA measures the resistance (impedance) to an applied alternating current. Variations in impedance can indicate differences in tissue composition, hydration levels and cellular integrity. This analysis helps the device identify areas of imbalance or dysfunction, which are then targeted for treatment.
The device uses both analogue and digital waveforms to deliver microcurrents. The choice of waveform—whether sinusoidal, square or complex—affects the penetration and interaction with biological tissues. For instance, a square wave might be used for deeper penetration due to its higher harmonic content.
Digital Signal Processing (DSP) techniques are employed to filter and analyze the bioelectrical signals. The device’s algorithms process the incoming signals to differentiate between normal and abnormal electrical patterns. This involves Fourier Transform techniques to analyze the frequency components of the bioelectrical signals, helping to pinpoint the exact location and nature of the impedance abnormalities.
The Electro-Equiscope® operates on a closed-loop control system, where continuous feedback from the body’s bioelectrical signals informs the adjustments in current output. This system relies on real-time data acquisition and processing to ensure the therapeutic currents are precisely modulated to achieve the desired effect.
Adaptive algorithms dynamically adjust the treatment parameters based on the body’s response. These algorithms use principles from control theory. The goal is to achieve homeostasis by normalizing the electrical activity in the affected tissues.
The application of microcurrents influences cellular electrodynamics, particularly by affecting the transmembrane potential. By restoring the normal electrical gradients across cell membranes, microcurrent therapy promotes cellular functions, such as nutrient transport, waste removal and ATP synthesis.
Inflammatory responses are often characterized by disrupted electrical patterns. The microcurrents help to re-establish normal electrical conductivity, thereby reducing inflammatory markers and promoting tissue repair. This effect is mediated through the modulation of ion channels and signaling pathways involved in inflammation.
The Electro-Equiscope® allows for precise control over several parameters:
The Electro-Equiscope® is an FDA Class II medical device, meaning it meets rigorous standards for safety and efficacy. It includes fail-safes and monitoring systems to prevent excessive current application and ensure patient safety.
Electrical Bioimpedance Monitoring is an emerging tool for biomedical research and for medical practice. It constitutes one of the diagnostic methods based on the study…
Here are few more examples on the subject of impedance looking at it from a different viewing angle. As a rule impedance always represents a ratio of a force or other physical imposition…
PLL stands for ‘Phase-Locked Loop’ and is basically a closed loop frequency control system, which functioning is based on the phase sensitive detection of phase difference between the input and output signals of the controlled oscillator.